The main reasons for the rapid deterioration of the oil in the wc series generator set include the following:
 
1. Incorrect oil brand or substandard quality: Using an unsuitable oil brand or substandard quality oil will cause the oil to deteriorate. For example, a generator set with a boost and a rated speed greater than 2000 rpm should use oil of grade CC or above.
 
‌2. Poor technical condition: The technical condition of the generator set is poor, such as blowby, oil blowby, excessive fit clearance or excessive oil temperature, which will cause the oil to deteriorate.


 
‌3. Poor working environment: The generator set often operates at low temperature, low load and low speed, the piston deformation is insufficient, the combustion is incomplete, and the diesel enters the oil pan along the cylinder wall to dilute and deteriorate the oil.
 
‌4. Exhaust gas enters the oil pan: Exhaust gas enters the oil pan and condenses into water and acidic substances, causing the oil to deteriorate.
 
‌5. Oil filter problem‌: The oil filter is dirty or damaged, and the unfiltered dirty oil enters the lubrication part, which will not only accelerate the deterioration of the oil, but also accelerate the wear of the parts‌.


 
‌6. Improper maintenance‌: Failure to clean the oil tank and pipes during maintenance, or not paying attention to the level and cleanliness of the oil when changing the oil, will cause the oil to deteriorate prematurely‌.
 
‌Methods to prevent the deterioration of the oil of the WC series generator set include‌:
 
‌1. Regularly replace the oil and filter element‌: Replace the oil and filter element according to the manufacturer's recommendations, and avoid using inferior or unsuitable oil.
2. Maintain the normal operating temperature of the engine‌: Avoid running the engine for a long time at low temperature, low load, and low speed.


 
3. Regular inspection and maintenance‌: Regularly check the technical condition of the generator set to ensure that all components are working properly and avoid problems such as gas blowby and oil blowby.
 
4‌. Correct maintenance‌: During maintenance, ensure that the oil tank and pipes are clean to avoid contaminating the new oil.

More information: http://www.fadianjisos.com/

Weifang, shandong province, China 中国 山东。潍坊

     Sales hotline: +8615905360672
         WhatsApp: +8615905360672
   Email address: huaquan@huaquanpower.com
  Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone,
                            Weifang City, Shandong Province
Company Name: SHANDONG HUAQUAN POWER CO.,LTD

Shandong Huaquan Power Co., Ltd.